Identification of single events in the HPGe detector: Comparison of various methods based on the analysis of simulated pulse shapes

dc.creatorBakalyarov, A. M.
dc.creatorBalysh, A. Ya.
dc.creatorBelyaev, S. T.
dc.creatorLebedev, V. I.
dc.creatorZhukov, S. V.
dc.date2002-03-12
dc.date.accessioned2026-07-25T17:31:25Z
dc.descriptionVarious methods of identification of single events in the HPGe detector are compared on the basis of a program especially designed to simulate pulse shape in a semi-conductor germanium detector. Capabilities of three following methods are shown: (1) an application of the library of single pulse shapes, (2) the single-parameter method, and (3) a separation on the basis of artificial neural networks. The analysis was done in the context of an application of all above-mentioned techniques in the energy interval around the expected neutrino less double beta decay of Ge-76 in the Heidelberg-Moscow experiment.
dc.description22 pages, 14 figures
dc.identifierhttps://arxiv.org/abs/hep-ex/0203017
dc.identifierhttp://arxiv.org/abs/hep-ex/0203017
dc.identifier.urihttps://dspace.dare.co.zw/handle/123456789/48411
dc.subjectHigh Energy Physics - Experiment
dc.titleIdentification of single events in the HPGe detector: Comparison of various methods based on the analysis of simulated pulse shapes
dc.typetext